FISCHERSCOPE X-RAY XDL X-ray fluorescence measuring device for manual as well as automated coating thickness measurements on decorative and protective coatings. They are universally applicable energy dispersive X-ray measuring instruments used for non-destructive thickness measurements as well as analysis of thin coatings for the measurements on mass-produced parts as well as printed circuit boards. FISCHERSCOPE X-RAY XDL is designed under the direction of practiced quality controllers following the international industrial standards.
Models
-
XDL 210: Plane support stage, fixed Z-axis
-
XDL 220: Plane support stage, motor-driven Z-axis
-
XDL 230: Manually operable XY-stage, motor-driven Z-axis
-
XDL 240: Motor-driven XY-stage that moves into the loading position automatically, when the protective hood is opened. Motor-driven programmable Z-axis
Applications
-
Measurement of electroplated mass-produced parts
-
Study of thin coatings like decorative chromium-plating
-
Examination of functional coatings in the electronics as well as semiconductor industries
-
Automated measurements such as printed circuit boards
-
Solution study in the electroplating
General Specification
- Intended use:Energy dispersive x-ray fluorescence measuring device (EDXRF) to find out thin coatings and solution study.
- Element range:Chlorine (17) to Uranium (92) - up to 24 elements simultaneously with option WinFTM̨̉ BASIC.
- Design:Bench top unit with upwards opening hood
- Measuring direction:Top down
X-Ray Source
- X-ray tube:Tungsten tube with beryllium window
- High voltage:Three steps: 30 kV, 40 kV, 50 kV
- Aperture (Collimator): 0.3 mm (11.8 mils), Optional: 0.1 mm (3.9 mils), 0.2 mm (7.9 mils), slot 0.3 x 0.05 mm (11.8 x 2 mils)
- Measurement spot: On the basis of measuring distance and on the aperture, the real measurement. Spot size is shown in the video image.
- Smallest measurement spot: approx. 0.2 mm (7.9 mils)
X-Ray Detection
- X-ray detector:Proportional counter tube
- Measuring distance:0 - 80 mm (0 - 3.2 in)
- Distance compensation with patented DCM technique for simplified measurements at changeable distances. For different applications or for higher needs on accuracy an extra calibration might be needed.
Sample Alignment
- Sample positioning:Manually
- Video microscope:High-resolution CCD color camera is designed for optical monitoring of the position along the Cross hairs with a calibrated scale (ruler), spot-indicator, Adjustable LED illumination and primary beam axis.
- Zoom factor:Digital 1x, 2x, 3x, 4x
Evaluation Unit
- Computer:Windows̨̉-PC
- Software:Standard: Fischer WinFTM̨̉ LIGHT
Optional: Fischer WinFTM̨̉ BASIC, PDM̨̉, SUPER
Sample support stage
Sample Stage | ||||
| XDL 210 | XDL 220 | XDL 230 | XDL 240 |
Design | Fixed sample Support | Fixed sample Support | Manual XY-stage | Programmable XY-stage |
Maximum travel XY | - | - | 95 x 150 mm (3.7 x 5.9 in) | 255 x 235 mm (10 x 9.2 in) |
Travel speed XY | - | - | - | 80 mm/s (3.1 in/s) |
Repeatability precision XY | - | - | - | 0,01 mm (0.4 mils)(*1) |
Usable sample placement area | 463 x 500 mm (18.2 x 19.7 in) | 463 x 500 mm (18.2 x 19.7 in) | 420 x 450 mm (16.5 x 17.7 in) | 300 x 350 mm (11.8 x 13.8 in) |
Z axis | Fixed Position (Top/Middle/Bottom) | Electrically adjustable | Electrically adjustable | Programmable |
Travel Z axis | - | 140 mm (5.5 in) | 140 mm (5.5 in) | 140 mm (5.5 in) |
Max. sample weight | 20 kg (44 lb) | 20 kg (44 lb) | 20 kg (44 lb) | 5 kg (11 lb) / 20 kg (44 lb)(*2) |
Max. sample height | 155/90/25 mm (6/3.5/1 in) | 140 mm (5.5 in) | 140 mm (5.5 in) | 140 mm (5.5 in) |
Laser pointer (class 1) to | - | - | Yes | Yes |
Electrical Data
- Power supply:AC 115 V or AC 230 V 50 / 60 Hz
- Power consumption:max. 120 W, without evaluation PC
- Protection class:IP40
Dimensions
- External dimensions:Width x depth x height [mm]: 570 x 760 x 650 mm, [in]: 22 x 30 x 26
- Interior dimensions:Width x depth x height [mm]: 460 x 495 x see max. sample height measurement:
- chamber:[in]: 18 x 19.5 x 26 x see max. sample height
- Weight:XDL 210: 94 kg (207 lb); XDL 220: 99 kg (218 lb); XDL 230: 107 kg (235 lb);XDL 240: 120 kg (264 lb)
Environmental Conditions
- Operating temperature:10oC- 40oC / 50oF o104oF
- Storage/Transport 0oC - 50oC / 32oF - 122oF temperature:
- Admissible air humidity: 95 %, non-condensing
Standards
- CE approval:EN 61010
- X-Ray standards:DIN ISO 3497 and ASTM B 568
- Approval:Fully protected device with type approval according to the German regulations.
Product details
Repeatability | Greater than 1 % for gold,measurement time 60 sec |
Brand | Fischer |
Power Type | Electric |
Operation Mode | Automatic |
Dimension | 403 x 588 x 365 mm |
Power Supply | AC 230 V 50 / 60 Hz |