- Home »
- Our Products »
- PVD & CVD Coating »
- Fischerscope X-ray XDAL
- These are uniquely designed and developed with high-precision, programmable XY-stage and an electrically.
- These are user-friendly bench-top instruments acclaimed for sample stage moves into the loading position automatically, when the protective hood is opened.
- These are compact sized, robust designed and ensure longer stability. Its laser pointer works as a positioning aid and supports the quick alignment of the sample to be measured.
- These are operated through the powerful and user-friendly WinFTM® software and designed as per German regulations Deutsche Röntgenverordnung-rov". Its entire operation and evaluation of measurements as well as the clear presentation of measurement data is performed on a PC through software.
Typical areas of application are:
- Analysis of very thin coatings of ⤠0.1 μm (0.004 mils)
- Measurements of functional coatings in the electronics and semiconductor industries
- Determination of complex multi-coating systems
- Automated measurements, e.g., in quality control
- Determination of the lead content in solder
General Specification
- Intended use:Energy dispersive X-ray fluorescence measuring instrument (EDXRF) to determine thin coatings and alloys
- Element range:Aluminum Al (13) to Uranium U (92) â up to 24 elements simultaneously
- Design:Bench-top unit with hood opening upwards XY-stage and Z-axis electrically driven and programmable,Motor-driven changeable apertures and filters Video camera and laser pointer (class 1) for orienting the sample
- Measuring direction:Top down
X-Ray Source
- X-ray tubeMicro focus tungsten tube with beryllium window
- High voltageThree steps 10 kV, 30 kV, 50 kV
- Aperture (Collimator):4x changeable: Ã 0.1 mm (3.9 mils), Ã 0.3 mm (11.8 mils), Ã 0.6 mm (23.6 mils) slot 0.5 x 0.15 mm (19.7 x 5.9 mils), others on request
- Primary filter:3x changeable (Standard configuration: Nickel, Aluminum, no filter)
- Measurement spot:Depending on the measuring distance and on the aperture, the actual spot size is shown in the video image. Smallest measurement approx. Ã 0.15 mm (5.9 mils) with aperture 0.1 mm (3.9 mils)
X-Ray Detection
- X-ray detectorSilicon PIN detector with peltier cooling
- Resolution (fwhm for Mn-Kα)⤠200 eV
- Measurement distance:0 ⦠80 mm (0 ⦠3.2 in) Distance compensation with patented DCM method for simplified measurements at varying distances. For particular applications or for higher demands on accuracy an additional calibration might be necessary.
Sample Alignment
- Video microscopeHigh-resolution CCD color camera for optical monitoring of the measurement location along the primary beam axis,manual focusing and auto-focus, crosshairs with a calibrated scale (ruler) and spot-indicator,adjustable LED illumination, laser pointer (class 1) to support accurate sample placement.
- Zoom factorDigital 1x, 2x, 3x, 4x
Sample Stage
- Design Programmable, motor-driven XY-stage
- Maximum travel X/Y-axis: 255 x 235 mm (10 x 9 in); Z-axis: 140 mm (5 in)
- Max. travel speed 80 mm/s (3.2 in/s)
- Repeatability precision XY ⤠0.01 mm (0.4 mils), unidirectional
- Usable sample placement area Width x depth [mm]: 300 x 350 mm, [in]: 12 x 14
- Max. sample weight 5 kg, with reduced approach travel precision 20 kg
- Max. sample height 140 mm (5.5 in)
Electrical Data
- Power supplyAC 115 V or AC 230 V 50 / 60 Hz
- Power consumptionMax. 120 W ,without evaluation PC
- Protection classIP40
Dimensions
- External dimensions Width x depth x height [mm]:570 x 760 x 650 mm, [in]: 22 x 30 x 26
- Interior dimensions Width x depth x height [mm]: measurement chamber460 x 495 x 146 mm, [in]: 18 x 19.5 x 5.7
- Weight Approx. 115 kg (52 lb)
Environmental Conditions
- Temperature: Operation10 °C â 40 °C / 50 °F â 104 °F
- Temperature Storage/Transport:0 °C â 50 °C / 32 °F â 122 °F
- Admissible air humidity⤠95 %, non-condensing
Evaluation Unit
- ComputerWindows®-PC
- Software Standard: Fischer WinFTM® BASIC including PDM®, Optional: Fischer WinFTM® SUPER
Standards
- CE approval EN 61010
- X-Ray standards DIN ISO 3497 and ASTM B 568
- Approval Fully protected instrument with type approval according to the German regulations "Deutsche Röntgenverordnung-RöV".
Product details
Repeatability | Greater than 1 % for gold,measurement time 60 sec |
Brand | Fischer |
Power Type | Electric |
Operation Mode | Automatic |
Dimension | 403 x 588 x 365 mm |
Power Supply | AC 230 V 50 / 60 Hz |