* * * This website is currently in expired state. * * *

Coating Thickness
Call Me Free
Fischer measurement Technologies (India) Pvt. Ltd.

Gold Testing Machine XDAL-237 XDAL-237

Gold Testing Machine XDAL-237

Gold testing machine in hallmarking centres: XDAL237 is engineered under the firm direction of experienced quality controllers. These are widely used as X-ray fluorescence measuring instrument with a programmable XY-stage and Z-axis for automated measurements of thin coatings in Gold Hallmarking, Assaying and Manufacturing Centres.These are widely used for non-destructive measurements and analysing very thin coatings.

Design
  • These are uniquely designed and developed with high-precision, programmable XY-stage and an electrically.
  • These are user-friendly bench-top instruments acclaimed for sample stage moves into the loading position automatically, when the protective hood is opened.
  • These are compact sized, robust designed and ensure longer stability. Its laser pointer works as a positioning aid and supports the quick alignment of the sample to be measured.
  • These are operated through the powerful and user-friendly WinFTM® software and designed as per German regulations Deutsche Rontgenverordnung-rov". Its entire operation and evaluation of measurements as well as the clear presentation of measurement data is performed on a PC through software.
Typical areas of application are:
  • Analysis of very thin coatings of ≤ 0.1 μm (0.004 mils)
  • Measurements of functional coatings in the electronics and semiconductor industries
  • Determination of complex multi-coating systems
  • Automated measurements, e.g., in quality control
  • Determination of the lead content in solder

General Specification

  • Intended use: Energy dispersive X-ray fluorescence measuring instrument (EDXRF) to determine thin coatings and alloys
  • Element range:Aluminum Al (13) to Uranium U (92) – up to 24 elements simultaneously
  • Design:Bench-top unit with hood opening upwards XY-stage and Z-axis  electrically driven and programmable,Motor-driven changeable apertures and filters Video camera and laser pointer (class 1) for orienting the sample
  • Measuring direction: Top down

X-Ray Source

  • X-ray tube Micro focus tungsten tube with beryllium window
  • High voltage Three steps 10 kV, 30 kV, 50 kV
  • Aperture (Collimator):4x changeable: Ø 0.1 mm (3.9 mils), Ø 0.3 mm (11.8 mils), Ø 0.6 mm (23.6 mils) slot 0.5 x 0.15 mm (19.7 x 5.9 mils), others on request
  • Primary filter: 3x changeable (Standard configuration: Nickel, Aluminum, no filter)
  • Measurement spot: Depending on the measuring distance and on the aperture, the actual spot size is shown in the video image. Smallest measurement approx. Ø 0.15 mm (5.9 mils) with aperture 0.1 mm (3.9 mils)

X-Ray Detection

  • X-ray detector Silicon PIN detector with peltier cooling
  • Resolution (fwhm for Mn-Kα) ≤ 200 eV
  • Measurement distance:0 … 80 mm (0 … 3.2 in) Distance compensation with patented DCM method for simplified measurements at varying distances. For particular applications or for higher demands on accuracy an additional calibration might be necessary.

Sample Alignment

  • Video microscope High-resolution CCD color camera for optical monitoring of the measurement location along the primary beam axis,manual focusing and auto-focus, crosshairs with a calibrated scale (ruler) and spot-indicator,adjustable LED illumination, laser pointer (class 1) to support accurate sample placement.
  • Zoom factor Digital 1x, 2x, 3x, 4x

Sample Stage

  • Design Programmable, motor-driven XY-stage
  • Maximum travel X/Y-axis: 255 x 235 mm (10 x 9 in); Z-axis: 140 mm (5 in)
  • Max. travel speed 80 mm/s (3.2 in/s)
  • Repeatability precision XY ≤ 0.01 mm (0.4 mils), unidirectional
  • Usable sample placement area Width x depth [mm]: 300 x 350 mm, [in]: 12 x 14
  • Max. sample weight 5 kg, with reduced approach travel precision 20 kg
  • Max. sample height 140 mm (5.5 in)

Electrical Data

  • Power supply AC 115 V or AC 230 V 50 / 60 Hz
  • Power consumption Max. 120 W ,without evaluation PC
  • Protection class IP40

Dimensions

  • External dimensions Width x depth x height [mm]: 570 x 760 x 650 mm, [in]: 22 x 30 x 26
  • Interior dimensions Width x depth x height [mm]measurement chamber: 460 x 495 x 146 mm, [in]: 18 x 19.5 x 5.7
    Weight
    Approx. 115 kg (52 lb)

Environmental Conditions

  • Temperature: Operation10 °C – 40 °C / 50 °F – 104 °F
  • Temperature Storage/Transport: 0 °C – 50 °C / 32 °F – 122 °F
  • Admissible air humidity≤ 95 %, non-condensing

Evaluation Unit

  • Computer Windows®-PC
  • Software  Standard: Fischer WinFTM® BASIC including PDM®, Optional: Fischer WinFTM® SUPER

Standards

  • CE approval EN 61010
  • X-Ray standards DIN ISO 3497 and ASTM B 568
  • Approval Fully protected instrument with type approval according to the German regulations "Deutsche Rontgenverordnung-RoV

Product Details

Repeatability

Greater than 1 % for gold,measurement time 60 sec

Brand

Fischer

Power Type

Electric

Operation Mode

Automatic

Dimension

403 x 588 x 365 mm

Power Supply

AC 230 V 50 / 60 Hz

 

Max sample weight

5 kg,with reduced approach travel precision 20 kg

Max travel speed

80 mm/s (3.2 in/s)

Maximum travel

X/Y-axis 255 x 235 mm (10 x 9 in); Z-axis 140 mm (5 in)

Repeatability precision XY

0.01 mm (0.4 mils),unidirectional